Welcome to awslagi.com – Sharing AWS, Anthropic, Google Cloud, Microsoft Azure IT Exams. It's free for all!

Cisco and NetApp FlexPod Design

Prove your ability to design high-performance FlexPod solutions for complex enterprise workloads.

4.8★★★★★(343 ratings)
21,379 studentsIntermediate
This exam focuses on the design phase of FlexPod deployments. You will learn to gather requirements, size compute and storage correctly, and architect resilient converged systems that meet specific business service level agreements (SLAs). Design the future of the enterprise data center. This architectural credential proves you can create reliable, scalable infrastructure from the ground up, making you a vital asset for large-scale digital transformation projects.

What you'll learn

  • Sizing FlexPod components
  • Resilient architecture design
  • Mapping workloads to FlexPod
  • Converged solution validation
  • Advanced UCS and ONTAP design

NS0-175

Lectures1
Questions17
Duration30 week
Students21,379

$20.00

Full Free Question Bank (17 Questions)

Cisco and NetApp FlexPod Design (NS0-175) Practice Questions & Verified Answers

Click any option to test your knowledge, or reveal the verified answer and detailed explanation below each question.

Question #1Part 1Select 2

You are sizing a FlexPod Datacenter solution for multitenancy use. What are two important platform scaling considerations in this scenario? (Choose two.)

Amaximum NetApp ONTAP cluster limits
Bmaximum NetApp ONTAP storage VM limits
Cmaximum Cisco vPC interfaces between Fabric Interconnects
Dmaximum Cisco L1, L2 interfaces between Fabric Interconnects
Question #2Part 1

A customer wants to use a Cisco Nexus 93180YC-FX switch to support the FC protocol for booting from SAN without having to deploy additional Cisco 900 Series MDS switches in their FlexPod Datacenter configuration. In this scenario, what is required for this solution?

AThe customer must enable the FC license on the 93180YC-FX switch
BThe customer must deploy the 93180YC-FX switch as part of a Cisco ACI fabric
CThe customer must directly connect the NetApp AFF system to the Cisco UCS Fabric Interconnects
DThe customer must add an expansion FC module to the 93180YC-FX switch
Question #3Part 1Select 2

You are designing a multi-site FlexPod Datacenter solution for a customer using MetroCluster over IP. The design should include a single set of compliant switches for the environment. Which two features are required to satisfy this requirement? (Choose two.)

Asupport for Fibre Channel ports
Bsupport for an MTU size of 9216
Csupport for unified switch ports
Dsupport for QoS
Question #4Part 1Select 3

You have a FlexPod solution that consists of a NetApp AFF A800 storage system, a Cisco MDS 9148S switch, and a Cisco UCS 6232 Fabric Interconnect. You want to upgrade NetApp ONTAP software on the AFF A800 to take advantage of a new feature. In this scenario, which three tools would enable you to verify if the upgrade would be performed safely? (Choose three.)

ANetApp Interoperability Matrix Tool
BCisco Intersight
CCisco Data Center Network Manager
DCisco UCS Hardware and Software Compatibility List
ENetApp Active IQ Upgrade Advisor
Question #5Part 1Select 3

What are three requirements for all FlexPod Datacenter solutions? (Choose three.)

Atwo NetApp storage controllers in a high-availability (HA) pair configuration
Ba separate 100 Mbps Ethernet/1 Gbps Ethernet out-of-band management network
Ca pair of Fabric Extenders in a redundant configuration
Dtwo Cisco UCS 6200, 6300, or 6400 Series Fabric Interconnects in a redundant configuration
Eredundant boot-from-SAN LUN paths
Question #6Part 1

A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they realize they have six rack units of space remaining. They need to install as many servers as possible in this available rack space. In this scenario, which solution allows them to accomplish their objective?

Athree Cisco UCS C4200 rack servers
Bfour Cisco UCS B480 M blade servers
Csix Cisco UCS C220 M5 rack servers
Deight Cisco UCS B200 M5 blade servers
Question #7Part 1Select 2

A customer is verifying that they have separation on their FC switch fabric to protect their FlexPod solution from their other storage devices. Which two technologies enable the customer to accomplish this task? (Choose two.)

AWWPN zoning
BVASN
CIQN igroup
DVLAN
Question #8Part 1Select 3

A customer is deploying a FlexPod Datacenter and planning to boot from SAN each their UCS blades using the Fibre Channel Protocol. In this scenario, which three actions would accomplish their objective? (Choose three.)

AUse only a pair of Cisco Nexus 9318YC-FX switches
BCreate an igroup on the NetApp ONTAP storage system with the appropriate IQNs
CUse only a pair of Cisco Nexus 9336C-FX2 switches
DUse a pair of Cisco MDS 9148T and a fair of Cisco 9336C-FX2 switches together
ECreate an igroup on the NetApp ONTAP storage system with the appropriate WWPNs
Question #9Part 1Select 3

A customer is unhappy with their current data center infrastructure. They want to purchase a FlexPod system to replace it. The customer asks you to help them understand the benefits of Solution Support to determine which support model would suit them best. In this scenario, which three statements are correct? (Choose three.)

AYou have a single point of contact for all cases
BSolution Support is a lower-cost support option
CThere is no need to diagnose the problem before you call support
DCustomers do not need to open tickets; all issues are automatically reported
EIssues are solved by solution experts
Question #10Part 1

Your environment currently has a 12-node NetApp cluster serving iSCSI. You need to add at least four more nodes to serve FC to your environment. In this scenario, what should you do?

AYou can safely add up to 4 more storage controllers in the current cluster
BYou can safely add up to 6 more storage controllers in the current cluster
CYou must create a new cluster with the new storage controllers
DYou can safely add up to 12 more storage controllers in the current cluster
Question #11Part 1

A customer plans to decommission a Cisco UCS B-Series server, as part of this action, the customer disassociates the service profile from the currently assigned server. Which action is performed by UCS Manager in this scenario?

AIt reboots the primary Fabric Interconnect immediately
BIt recalculates the power allotment for each blade server within the chassis
CIt reboots the secondary Fabric Interconnect immediately
DIt powers down the server
Question #12Part 1Select 3

You are designing a FlexPod solution with secure multitenancy for a company. Each department in the company wants to use their own storage and to be integrated with Windows Active Directory. In this scenario, which three technologies should be included in the design? (Choose three.)

AIPspaces
BNVMe
CS3
DCIFS
EStorage Virtual Machine
Question #13Part 1

You want to ass a customer’s NetApp storage controllers into their Cisco Intersight management portal. In this scenario, which IP address would you choose to add?

ANetApp SVM management IP address
BNetApp Active IQ Unified Manager IP address
CNetApp cluster IP address
DNetApp Virtual Storage Console IP address
Question #14Part 1

You want to direct-connect NetApp storage to a UCS Mini over IP. In this scenario, which storage protocol is supported?

ACIFS
BFC
CS3
DiSCSI
Question #15Part 1Select 2

You are designing a FlexPod solution that requires 100GbE connectivity between all components. In this scenario, what are two NetApp Controller types that would satisfy the requirement? (Choose two.)

ANetApp AFF A220
BNetApp AFF C190
CNetApp AFF A800
DNetApp AFF A400
Question #16Part 1Select 2

A customer is designing a FlexPod solution that must satisfy the requirements shown below: -- have disaster recovery to an alternative data center, -- must have continuous replication of data for a database, -- must leverage a 100Gbps capable switch, -- have a maximum distance of 700 km. In this scenario, which two components would be used to satisfy the requirements? (Choose two.)

AMetroCluster FC
BCisco Nexus 3232C
CMetroCluster IP
DCisco MDS 9132T
Question #17Part 1Select 2

A customer has decided to deploy Red Hat OpenShift on a FlexPod solution, based in a published Cisco Validated Design. The customer intends to use the NetApp Trident to attach persistent storage to the customer’s containers from the customer’s NetApp AFF controllers. In this scenario, which two storage protocols are supported? (Choose two.)

AiSCSI
BFC
CNFS
DSMB

📢 Unlock Full Access to Success!

"The content displayed here is a promotional preview and contains only 50% of the actual exam database. To access the complete set of updated questions, please upgrade to the Full Version."

👉 Click the button and follow the instructions to secure your full access immediately!