Welcome to awslagi.com – Sharing AWS, Google Cloud, Microsoft Azure IT Exams. It's free for all!

HPE7-A11: HPE Aruba Networking Certified Professional - Campus Access Architect

Master the HP / HPE HPE Aruba Networking Certified Professional - Campus Access Architect (HPE7-A11) certification exam with 40 realistic practice questions covering Analyze requirements, Propose the solution, New technologies, Discover customers' requirements.

4.8★★★★★(358 ratings)
20,862 studentsAdvanced
Prepare for the HP / HPE HPE Aruba Networking Certified Professional - Campus Access Architect (HPE7-A11) certification with scenario-based practice questions modeled on real exam objectives. You will build practical confidence across key domains including Analyze requirements, Propose the solution, New technologies, Discover customers' requirements. Each question includes structured answer options and hint answers to help you identify knowledge gaps quickly, reinforce core HP / HPE concepts, and pass the HPE7-A11 exam on your first attempt.

What you'll learn

  • Analyze requirements
  • Propose the solution
  • New technologies
  • Discover customers' requirements
  • Architect the solution

HPE7-A11

Lectures1
Questions38
Duration30 week
Students20,862

$20.00

Full Free Question Bank (38 Questions)

HPE7-A11: HPE Aruba Networking Certified Professional - Campus Access Architect (HPE7-A11) Practice Questions & Verified Answers

Click any option to test your knowledge, or reveal the verified answer and detailed explanation below each question.

Question #1Part 1Analyze requirements

Under which condition is a Mode Conditioning Patch Cable necessary?

AA 1000Base-SX Transceiver is operated with 62.5/125 cables up to 500 m.
BA 1000Base-LX Transceiver is operated with 62.5/125 cables up to 500 m.
CA 10GBase-LX4 Transceiver is operated with 62.5/125 cables up to 2 km.
DA 10GBase-LR Transceiver is operated with 62.5/125 cables up to 500 m.
Question #2Part 1Propose the solution

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is inadequately served by its existing L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will offer public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will mainly connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of “smart office” technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants redundant RADIUS resources in each of its three geographic regions: AMER, EMEA, and APAC. A large office location in each region has sufficient VMware resources available. Each region has between 4,481 and 5,692 clients, all of which must perform either 802.1X wired or wireless authentication, as well as 802.1X authentication for one personal Wi-Fi device. All non-personal devices must also validate health using a local agent. A total of 500 guests are expected to be connected on average, with a maximum of 700 simultaneous connections using Guest Portal for Internet access. TACACS authentication will also be configured for 1200 evenly distributed NADs. How many OnGuard Licenses are required in this scenario?

A5,000
B25,000
C35,000
D15,000
Question #3Part 1Propose the solution

XYZ Regional Hospital is an integrated healthcare system comprising hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital has recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired access, and AAA solutions are outdated and must be replaced. XYZ Regional Hospital wants to future-proof and improve efficiency at all sites by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that delivers uninterrupted availability of all systems. Locations: - XYZ Regional Hospital is located in New York City - Dila Health Center is located in City A - Mount Health Center is located in City B - Rock Health Center is located in City C - Branch clinics are located at different locations across the United States Requirements: - Provide, through management software, a single pane of glass to manage wired and wireless LANs and VPNs across campus, branch, and remote environments through a web/cloud architecture that provides near-real-time insight, troubleshooting tools, and Service Level performance reporting. - Seamless integration across wired, wireless, WAN, SD-Branch, and IoT - Provide secure wireless access for all Regional Hospital employees and partners, and wireless Internet access for medical citizens when they visit the facilities. - All access points must support these features and specifications: 802.11 ax (Wi-Fi 6E Certified) - Security options including WP2/WPA3 and 802.1X with Radius secure authentication - Identify and authenticate every wireless and wired device - End-to-end role-based security - Seamless mobility across the hospital for medical teams, patients, and visitors - Cut Wi-Fi deployment times from days to hours and enable Zero-Touch deployments across the site - Establish a resilient, future-ready network infrastructure with the intelligence, scalability, and intuitive toolsets to meet emerging needs - Fully redundant branch solution with dynamic path selection to the hospital The hospital IT director is concerned that branch clinics will lack an onsite resource to troubleshoot issues that may arise and wants a solution that enables the hospital IT team to proactively monitor the branch offices. Requirements: - Monitor wireless and wired connections - Provide an end-to-end experience view that identifies points of failure - Proactively troubleshoot issues that affect application performance What is the correct solution?

AClient Insight
BAirWave
CHPE Aruba Networking User Experience Insight
DHPE Aruba Networking ClearPass Device Insight
Question #4Part 1New technologiesSelect 2

What distinguishes OM4 cabling from OM5 cabling? (Choose two.)

AOМ5 supports speeds up to 100 Gbps, while OM4 does not.
BOM5 is approved as Wide Band Multimode Fiber (WBMMF), while OM4 is not.
COM4 supports distances up to 100 m. while OM5 supports distances up to 150 m using 100 GBps transceivers.
DOM5 supports Multiplexing operating in the 850 to 950 nm range, while OM4 does not.
Question #5Part 1Propose the solution

You are taking part in a joint technical and business review with a customer that plans to deploy HPE Aruba Networking User Experience Insight (UXI) across multiple sites. The customer has a large campus with several buildings and smaller remote offices, and is assessing UXI as part of its digital-experience monitoring strategy. During the review, the technical team is concentrating on deployment best practices and technical capabilities, while business stakeholders are concerned about deployment efficiency, cost justification, and ensuring the sensors deliver actionable visibility throughout the environment. You are asked to provide validated deployment guidance and correct any misconceptions about UXI capabilities and deployment options. What is a valid recommendation for UXI deployment options?

ASensors should be installed at the finished ceiling level, not above the false ceiling.
BSensors can test up to 4 wired and 4 wireless networks per test cycle.
CSensors should be deployed in approximately a 1:5 to 1:8 UXI to AP ratio at the campus.
DEach UXI test cycle can support up to a maximum of 10 configured tests.
Question #6Part 1Discover customers' requirements

Which licenses are required to use the UXI Client on Zebra devices?

AUXI Cloud Subscription
BWireless Insights
CUXI Agent Subscription
DUXI LTE Subscription
Question #7Part 1Architect the solution

Which documentation resources can be used to find validated information about HPE Aruba Networking products that helps the architect build the solution design?

Avalidated Solution Guide
Bproduct reviews (CNET, Network World)
Cconfiguration guides
Dcompetitive documentation
Edata sheets
Question #8Part 1Analyze requirementsSelect 2

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mixture of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will be used. The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has supplied floorplans, wall density, and ceiling heights for the wireless deployment in the carpeted office space. What additional information is needed to produce an accurate bill of material? (Choose two.)

Aflooring information
BPoE port details
Cceiling construction details
Dsprinkler details
Question #9Part 1Propose the solutionSelect 2

You are creating a wireless intrusion detection and prevention strategy (WIDS/WIPS) for a client’s enterprise network with HPE Aruba Networking and AOS-10. As part of the design, you intend to deploy dedicated Air Monitors (AMs). Which two statements are consistent with HPE Aruba Networking best practices for deploying AMs in an AOS-10 environment? (Choose two.)

AIt is recommended to deploy four or five AMs per 10,000 sq ft (930 sq m) as a starting point.
BDetection of infrastructure threats is enabled by default at the "Low" setting. Raise it after confirming there are no false positive matches.
CDeauthenticate containment is disabled by default, which is recommended only after consulting with security and legal stakeholders.
DAOS-10 APs operating in "radio mode" act as Hybrid AMs and scan the 4.9 GHz public safety band for local security alerts.
EThere is no HPE Aruba Networking advised legal risk to recommending enabling "40MHz Intolerance" in the radio profile settings.
Question #10Part 1Propose the solution

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are out of scope for this project. The customer is underserved by its existing L2-based network infrastructure and wants to apply modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has decided to manage two wiring closets as one stack totaling 10 switches, with a minimum transport speed of 25Gbps over OM4 MM fiber. They also want to minimize stacking-cabling cost. Which switch series would most economically meet these requirements?

A6200F Switch Series
B6300F Switch Series
C6400 Switch Series
D6100 Switch Series
Question #11Part 1Propose the solutionSelect 2

Manufacturing A.B.C. is an international, mid-sized company that specializes in producing industrial equipment. It has operated in the market for more than two decades and has established itself as a reputable industry player. However, rapid technological advances have left its current network infrastructure outdated and unable to keep pace with the requirements of modern manufacturing processes. Manufacturing A.B.C.'s network combines multi-vendor legacy wired and wireless components, resulting in frequent downtime and reduced production efficiency. The aging equipment causes slow data-transfer rates, unreliable connectivity, and greater exposure to cyber threats. Fiber cabling also needs upgrading, as OM2 is used predominantly. Further complicating these network issues, the recent CTO departure has left the company without clear direction for the network-refresh project. The management team has not reached consensus on the scope, budget, or timeline for the upgrade. The manufacturing customer's primary objectives are as follows: - Improve network performance and reliability to enhance production processes and minimize downtime. - Enhance network security to protect sensitive data and intellectual property. - Streamline communication and collaboration among the organization's different departments. - Ensure scalability for future growth and technological advancements. Manufacturing A.B.C. is seeking a comprehensive network refresh that includes the following components: - Upgrade the wired infrastructure to high-speed Ethernet switches to support higher data-transfer rates and reduce latency. - Implement a robust wireless solution with enterprise-grade access points to provide seamless connectivity throughout the manufacturing facility. - Use centralized network-management tools to simplify network administration and monitoring. Expectations: The customer expects the network-refresh project to be completed efficiently, with minimal disruption to ongoing operations. They seek a reliable, experienced network-solutions provider that understands their unique manufacturing requirements and can deliver a customized solution aligned with their budget constraints. Given the recent CTO change, the manufacturing customer is eager to receive clear project proposals and decision-making support. As a network-solutions provider, your role is to address these concerns, provide expert guidance, and present a clearly defined plan that meets their objectives effectively. A manufacturing customer runs a 24/7 production facility and is concerned that the migration could disrupt the production chain. What are two ways to minimize or eliminate this disruption? (Choose two.)

AWhenever possible, ramp up the new infrastructure in parallel and do transparent switching from old to new core switch.
BClose the production site for at least 1 day to do the full migration in a single service window.
CReplace one access switch at a time and patch the ports by using a patch plan.
DCreate a migration plan which describes a phased approach, i.e. access layer first, distribution layer second, etc.
Question #12Part 1Discover customers' requirementsSelect 2

XYZ Regional Hospital is an integrated healthcare system consisting of hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and must be replaced. XYZ Regional Hospital wants to future-proof and improve efficiency at all sites by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability of all systems. Locations: - XYZ Regional Hospital is located in New York City - Dila Health Center is located in City A - Mount Health Center is located in City B - Rock Health Center is located in City C - Branch clinics are located at different locations across the United States Requirements: - Provide, through management software, a single pane of glass to manage wired and wireless LANs and VPNs across campus, branch, and remote environments through a web/cloud architecture that provides near real-time insight, troubleshooting tools, and Service Level performance reporting. - Seamless integration across wired, wireless, WAN, SD-Branch, and IoT - Provide secure wireless access for all Regional Hospital employees and partners, and provide wireless Internet access to medical citizens when they visit our facilities. - All access points must support these features and specifications: 802.11 ax (Wi-Fi 6E Certified) - Security options including WP2/WPA3 and 802.1X with Radius secure authentication - Identify and authenticate every wireless and wired device - End-to-end role-based security - Seamless mobility throughout the hospital for medical teams, patients, and visitors - Reduce Wi-Fi deployment times from days to hours and enable Zero-Touch deployments across the site - Establish a resilient, future-ready network infrastructure with the intelligence, scalability, and intuitive toolsets to meet emerging needs - Fully redundant branch solution with dynamic path selection to the hospital XYZ Regional Hospital plans a wireless site survey at its main campus. It must address recurring Wi-Fi coverage issues. Which pieces of information are required? (Choose two.)

AExisting wireless SSIDs and authentication methods
BCampus building floor plans or blueprints
CNumber of devices and device types at the branch clinics
DIf there are latency-sensitive applications present
ETotal square footage or square meters of the main campus
Question #13Part 1Analyze requirements

Which uplink oversubscription ratios satisfy A.B.C.'s requirements, assuming they can be adjusted later based on actual performance and capacity requirements?

A12:1
B4:1
C7:1
D24:1
E1:10
Question #14Part 1Propose the solution

XYZ Regional Hospital is an integrated healthcare system comprising hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and require replacement. XYZ Regional Hospital wants to future-proof and improve efficiency across every site by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability of all systems. Locations: - XYZ Regional Hospital is located in New York City. - Dila Health Center is located in City

A1x 3010 as a Publisher for the main DC1x 3010 as a Standby Publisher for the DR2x 3010 as Subscribers for the Main Hospital2x C2020 as Subscribers for the Dila Health Center2x C2020 as Subscribers for the Mount Health Center2x C2020 as Subscribers for the Rock Health Center25k + 10k Access licenses
B1x 3010 as a Publisher for the main DC1x C2020 as a Standby Publisher for the DR2x C2020 as Subscribers for the Main Hospital2x C1000 as Subscribers for the Dila Health Center2x C1000 as Subscribers for the Mount Health Center2x VMs as Subscribers for the Rock Health Center15k + 10k Access licenses
C1x C3010 as a Publisher for the main DC1x C3010 as a Standby Publisher for the DR2x C3010 as Subscribers for the Main Hospital2x C1000 as Subscribers for the Dila Health Center2x VMs as Subscribers for the Mount Health Center2x VMs as Subscribers for the Rock Health Center35k Access licenses
D1x 3010 as a Publisher for the main DC1x 3010 as a Standby Publisher for the DR2x 3010 as Subscribers for the Main Hospital2x C1000 as Subscribers for the Dila Health Center2x VMs as Subscribers for the Mount Health Center2x C2020 as Subscribers for the Rock Health Center15k + 10k Access licenses
Question #15Part 1Propose the solution

A global cruise line company needs to modernize its existing fleet. It will refresh the ship’s “insides” to improve cost-effectiveness and sustainability, replacing all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will always involve a hardware refresh. The project begins with the smallest ship, which has a maximum of 800 guests. Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Every cabin and technical room receives one access switch. The ship’s cabling structure will remain unchanged. Each IDF connects to the MDF through SMF, with two pairs available for the interconnect between core and distribution. The SMF distance between MDF and IDF is under 300 meters (980 ft), and it is OS1. Each cabin connects to the IDF through a single OM2 pair, with a maximum distance of 60 meters (200 ft). Each technical room connects to the IDF through a single OM2 pair, with distances from 100 to 150 meters (320 to 500 ft). For every cabin and technical room, the customer wants to replace the existing fan-less 2530/2540 switches without changing requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. It uses 200/300 series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no WLAN requirement changes. The cruise line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will provide 99.8% uptime, needed to keep paid guest Wi-Fi operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed. Based on best practices, what optic type should be recommended for the connection between the IDF and the cabins?

A10G BASE-T SFP+ RJ-45 30 m Cat6A Transceiver
B10G SFP+ LC LRM 220 m MMF Transceiver
C10G SFP+ LC SR 300 m MMF Transceiver
D10G LC BiDi 40 km-D 1330/1270 XCVR
Question #16Part 1Discover customers' requirementsSelect 2

Which two items are concerns for C-level executives and managerial stakeholders? (Choose two.)

AWhat is the projected growth for the company and how will this affect critical business requirements?
BHow to minimize the total cost of ownership which considering proposals for network expansion?
CWhich CX supported routing protocols can scale the network during an upcoming building addition to the campus?
DHow to address admin support staff concerns with the additional training required for a non-homogeneous vender approach?
EWhat management tool would enable simplified access to network resources?
Question #17Part 1Discover customers' requirementsSelect 2

You are meeting with different stakeholders in a customer’s IT organization as part of an HPE Aruba Networking campus access-layer design project. You need to collect technical input that supports design decisions, including switch-port capacity, uplink requirements, and user-connectivity needs. Which two stakeholders participate in these design activities? (Choose two.)

ADirector of Security Compliance
BNetwork Engineering Manager
CChief Financial Officer (CFO)
DHuman Resources Manager
EChief Operating Officer (COO)
Question #18Part 1Analyze requirements

Manufacturing A.B.C. is an international, mid-sized company that specializes in manufacturing industrial equipment. It has operated in the market for more than two decades and has become a reputable player in its industry. However, rapid technological advances have left its present network infrastructure outdated and unable to keep pace with modern manufacturing-process demands. Manufacturing A.B.C.'s network combines multi-vendor legacy wired and wireless components, resulting in frequent downtime and reduced production efficiency. Its aging equipment causes slow data-transfer rates, unreliable connectivity, and greater exposure to cyber threats. Fiber cabling should also be upgraded because OM2 is used for the most part. Further compounding the network problems, the recent departure of the CTO has left the company without a clear course for the network-refresh project. The management team lacks consensus on the upgrade's scope, budget, and timeline. The manufacturing customer's primary objectives are: - Improve network performance and reliability to improve production processes and minimize downtime. - Strengthen network security to safeguard sensitive data and intellectual property. - Streamline communication and collaboration among the organization's different departments. - Provide scalability for future growth and technological advances. Manufacturing A.B.C. wants a comprehensive network refresh that includes: - Upgrading the wired infrastructure with high-speed Ethernet switches to support higher data-transfer rates and lower latency. - Deploying a robust wireless solution using enterprise-grade access points to provide seamless connectivity throughout the manufacturing facility. - Centralized network-management tools to simplify network administration and monitoring. Expectations: The customer expects the network-refresh project to be completed efficiently, with minimal disruption to ongoing operations. They want a reliable, experienced network-solutions provider that understands their distinctive manufacturing requirements and can deliver a tailored solution that meets their budget constraints. Given the recent CTO change, the manufacturing customer is eager to receive clear project proposals and decision-making support. As the network-solutions provider, your role is to address these concerns, provide expert guidance, and present a clearly defined plan that effectively meets their objectives. Assume that the current network infrastructure has no wireless shadow-IT equipment operating across the different floors/production sites, but you want to confirm this. How can you determine whether wireless shadow-IT equipment is currently in operation?

ADo a ping sweep and document the hostnames/responses. Find out the connected switch port and walk to this location.
BAsk employees if they use 3rd party equipment to create isolated Hotspots.
CDo a passive site survey, analyze the outcome together with the customer, and decommission this equipment wherever possible.
DUse a wireless sniffer like Wireshark to scan the environment and look for anomalies.
Question #19Part 1Propose the solution

A global cruise-line company needs to refresh its current fleet. It will refresh the ship’s internal infrastructure to be cost-effective and improve sustainability. It will replace all WLAN/LAN hardware on the ship. As part of this refresh, the company will not change its existing security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. The company will begin with the smallest ship, with a maximum of 800 guests. Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Each cabin and technical room receives a single access switch. The ship’s cabling infrastructure will not be replaced. Each IDF connects to the MDF over SMF, with two pairs available for the interconnect between core and distribution. The SMF length between the MDF and IDF is less than 300 meters (980 ft), and it is OS1 fiber. Each cabin connects to its IDF with one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to its IDF with one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft). For every cabin and technical room, the customer wants to replace its current fanless 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and the technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. Its WLAN infrastructure uses 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements. The cruise-line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will offer 99.8% uptime, needed to keep paid guest Wi-Fi continuously operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed. Based on best practices, what optic type should be recommended for the connection between the MDF and the IDFs?

A50G SFP56 LC SR 100 m MMF Transceiver
B10G SFP+ LC LR 10 km SMF Transceiver
C25G SFP28 LC eSR 400 m MMF Transceiver
D25G SFP28 LC LR 10 km SMF Transceiver
Question #20Part 1Propose the solution

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The lowest two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are outside this project’s scope. The customer is underserved by its current L2-based network infrastructure and wants to apply modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants to use lower-cost OS-CX switches in its wiring closets. It calculates that each closet will require a stack of qty 6 POE (AT) and qty 4 Gigabit Ethernet switches, stacked with low-cost DACs. Which switch series should you recommend?

ACX 6100
BCX 6000
CCX 6300F
DCX 6200M
Question #21Part 1Propose the solutionSelect 2

You are taking part in a multi-team design workshop for a large enterprise campus and data-center refresh project. The network engineering team has chosen an EVPN-VXLAN-based fabric to provide scalable Layer 2/3 services, enhance segmentation, and simplify future automation. As part of the session, you have been asked to contribute to the technical design recommendations document, which will form the basis for the project implementation plan. This includes recording best practices, control-plane design, and overlay requirements for the EVPN-VXLAN fabric. You need to identify the accurate core recommendations, required features, and key design functions to include in the proposal. What accurately describes core recommendations, requirements, features, or functions of EVPN-VXLAN fabrics? (Choose two.)

AOSPF is commonly used to establish Layer 3 underlay connectivity between VTEP loopback interfaces.
BEVPN-VXLAN overlays require all stub VTEPs to form full-mesh iBGP peerings with each other.
CRoute Distinguishers are used by VTEPs to control which peers receive EVPN route advertisements.
DBGP Route Reflectors (RRs) configured on eBGP routers enable routing between external and overlay networks.
EMP-BGP EVPN serves as the control plane for VXLAN overlays and can be orchestrated by NetConductor.
Question #22Part 1Propose the solution

Which statements correctly describe valid high-availability features (VSX or VSF) for AOS-CX switches commonly deployed in enterprise campus environments?

A6200 switches support VSF between all 6200 models in the series.
B6000 switches support 2-4 node VSF stacking
C9300 switches support VSX clustering
D5420 switches support VSX clustering or VSF stacking
Question #23Part 1Architect the solutionSelect 2

Manufacturing A.B.C. is a mid-sized international company that specializes in manufacturing industrial equipment. It has operated in the market for more than two decades and has become a reputable participant in its industry. However, rapid technological advances have left its existing network infrastructure outdated and unable to keep pace with modern manufacturing-process demands. Manufacturing A.B.C.'s network combines legacy wired and wireless components from multiple vendors, resulting in frequent downtime and reduced production efficiency. The aging equipment causes slow data-transfer rates, unreliable connectivity, and greater exposure to cyber threats. Fiber cabling must also be upgraded because OM2 is used for most of it. Further compounding the network problems, the CTO's recent departure has left the company without a clear direction for the network-refresh project. The management team lacks consensus on the upgrade's scope, budget, and timeline. The manufacturing customer's primary objectives are as follows: - Improve network performance and reliability to enhance production processes and minimize downtime. - Enhance network security to safeguard sensitive data and intellectual property. - Streamline communication and collaboration among the organization's different departments. - Ensure scalability to support future growth and technological advances. Manufacturing A.B.C. requires a comprehensive network refresh with these components: - Upgrade the wired infrastructure to high-speed Ethernet switches to support increased data-transfer rates and reduce latency. - Implement a robust wireless solution with enterprise-grade access points that provides seamless connectivity throughout the manufacturing facility. - Use centralized network-management tools to simplify network administration and monitoring. Expectations: The customer expects the network-refresh project to be completed efficiently, with minimal disruption to ongoing operations. They seek a reliable, experienced network-solutions provider that understands their specific manufacturing requirements and can deliver a customized solution consistent with their budget constraints. Given the recent CTO change, the manufacturing customer is eager to receive clear project proposals and decision-making support. As a network-solutions provider, your role is to address these concerns, provide expert guidance, and present a clearly defined plan to meet the objectives effectively. Manufacturing A.B.C. must regulate various traffic types with QoS, and the architect chose DWRR instead of SP queuing. Which switches support DWRR? (Choose two.)

ACX 6200
BCX 8360
CCX 4100
DCX 6100
Question #24Part 1Propose the solution

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are out of scope for this project. The customer is underserved by its existing L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These improvements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has decided that the more critical switch stacks supporting Contact Center resources must support greater than 600W of CL4 PoE and redundant power supplies. These stacks will have approximately six members. What is the most economical switch series choice that meets these requirements?

ACX 6100
BCX 6400
CCX 6300F
DCX 6200M
Question #25Part 1Propose the solution

XYZ Regional Hospital is an integrated healthcare system comprising hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and must be replaced. XYZ Regional Hospital wants to future-proof and improve efficiency across all sites by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability of all systems. Locations: - XYZ Regional Hospital is in New York City. - Dila Health Center is in City

AHPE Aruba Networking cellular bridges and AOS-CX switches with foundation subscriptions
BAOS-10 AP mesh, HPE Aruba Networking AirWave, and AOS-CX switches
CAOS-10 AP mesh and AOS-CX switches with foundation subscriptions
DInstant AOS-8 AP mesh and AOS-CX switches with advanced subscriptions
Question #26Part 1Propose the solution

What bandwidth is recommended for a VSX Inter-Switch Link?

AIt should be equal to the sum of the downlink ports' bandwidth.
BIt should be equal or higher than the speed of the uplink.
CIt should be equal to the sum of the uplink ports' bandwidth.
DIt should be the same speed as the one used for VSX Keepalive speed bandwidth.
Question #27Part 1Discover customers' requirements

During the stakeholder interview, an agenda is created to clarify customer expectations. The customer is concerned about future business requirements, with network scalability and flexibility being key. Which expectations should be considered to solve upcoming business problems?

Aanticipated growth
Bpain points
Ccritical needs
Dbusiness outcomes
Enetwork deployment
Question #28Part 1Architect the solution

You are a member of a cross-functional team developing a detailed design proposal for a customer deploying EVPN-VXLAN in a modern campus core and data center fabric. The customer is moving from a traditional VLAN-based Layer 2 design to a VXLAN-based overlay architecture to support segmentation scalability and automation. As the solution undergoes review, you are asked to contribute by identifying and explaining core technical behaviors and configuration considerations critical to the success of EVPN-VXLAN in this environment. Which statements accurately describe key characteristics of EVPN-VXLAN in modern campus or data center networks? (Choose two.)

AMP-BGP is utilized as the control plane that establishes GRE over UDP between VTEPs. known as VXLAN.
BARP suppression is supported in EVPN-VXLAN fabrics through host route information carried in EVPN Type-2 NLRI.
CVTEPs apply unique Route Distinguishers prefixes to NLRI records, enabling selective advertising.
DVirtual Network Based Tunneling (VBNT) is a term used to describe static segmentation based on EVPN-VXLAN.
Question #29Part 1Analyze requirementsSelect 2

Which statements correctly describe the Unified Communication (UCC) and Intelligent Call Handling (ICH) capabilities available in HPE Aruba Networking AOS-10, along with their associated subscription and configuration requirements? (Choose two.)

AUCC features are only supported when Advanced subscription licenses are assigned to AOS-10 APs.
BUCC must be explicitly enabled by an administrator in HPE Aruba Networking Central Global settings before it becomes active.
CDSCP tag rewriting is supported only for protocols automatically recognized by UCC; custom apps are not supported.
DICH must be enabled within each SSIDs WLAN Advanced settings to take effect.
EHPE Aruba Networking Central allows importing custom SIP profiles via Webhooks once UCC is licensed.
Question #30Part 1Propose the solutionSelect 2

You are planning a secure onboarding solution for a customer’s enterprise network. The plan includes HPE Aruba Networking ClearPass Policy Manager (CPPM) Onboard to simplify device onboarding and enforce security policies. Which critical design considerations and feature recommendations should be included in your proposal to ensure a smooth, effective implementation? (Choose two.)

AWith OpsRamp EST integration with Onboard you can issue and manage RadSec certificates on third-party NADs using ClearPass exchange.
BOnboard CAs EST server can issue and automatically renew certificates for HPE Aruba Networking Unified Infrastructure devices.
COnboard does not support acting as a Registration Authority in order to proxy certificate signing requests to an external CA.
DWhen hosting multiple PKI Certificate Authorities using ClearPass, the Onboard feature requires a Foundation plus Security subscription.
Question #31Part 1Discover customers' requirements

During a stakeholder interview, an agenda is developed to clarify their expectations for the network design project. Which two topics emphasize the customer's experience with their network?

AAnticipated business or location growth
BPain points that impact daily operations
CThe most critical issues reported from users of the network
DThe most critical needs the new network will provide
ELong-term strategies to improve processes
Question #32Part 1Propose the solution

XYZ Regional Hospital is an integrated healthcare system consisting of hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and require replacement. XYZ Regional Hospital wants to future-proof and improve efficiency at all sites by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability for all systems. Locations: - XYZ Regional Hospital is in New York City. - Dila Health Center is in City

AThe team will define and document a path for the current to future support model, including any staffing, skills, and professional development that is recommended.
BKickoff the project to identify the team members involved, review the deliverables, expectations, timeframes, and begin the discovery/data collection.
CMeet with ITS Network/Telecom and support staff following the knowledge transfer sessions to educate the ITS team on campus, data center, and network security options
DReview the potential design options and further scope deployment efforts, phased implementation approaches, enablement options, and operational expertise requirements.
Question #33Part 1Propose the solution

Refer to the exhibit. ![Question Image](https://cdn.examcademy.com/images/questions/1784144957902-m0t4z1ab.png) Your client is deploying an HPE Aruba Networking solution in which AOS-10 APs operate in bridged mode and connect directly to AOS-CX access switches in a campus environment. A leading security priority is to block user traffic to any destination classified by BrightCloud Web Classification as **“Bot Nets.”** You have been asked to review and confirm the appropriate technical steps for accurate identification, classification, and blocking of this traffic through Central-managed policies and AOS-CX integration. To block user access to the specified web destination(s) in this deployment model, which action should be taken?

AAdd an (access rules) rule type "Access Control" Web Category and select "Bot Nets" action Deny to your APs group.
BConfigure the switch to enforce auth-node client mode on AP edge ports with an unlimited max client setting'.
CAdd an (access rules) rule type "Blocked Page URL" and select "Bot Nets" collection action Deny to your AP’s group.
DAdd an (access rules) rule type "Access Control" Application Category and select "Bot Nets" action Deny to your APs group.
Question #34Part 1Propose the solution

A global cruise-line company must modernize its existing fleet. It will refresh the ship’s “insides” to reduce cost and improve sustainability, replacing all WLAN/LAN hardware. This refresh will retain the current security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will require a hardware refresh. The company will begin with its smallest ship, which accommodates a maximum of 800 guests. Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Every cabin and technical room receives a single access switch. The ship’s cabling infrastructure will not be replaced. Each IDF connects to the MDF through SMF, with two pairs available for the core-to-distribution interconnect. The SM fiber length between the MDF and IDF is under 300 meters (980 ft), and the fiber type is OS1. Each cabin connects to its IDF using one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to its IDF through one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft). For every cabin/technical room, the customer wants to replace its existing fan-less 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. It is based on 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements. The cruise-line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide 99.8% uptime, which is required to keep paid guest Wi-Fi operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed. Based on best practices, which switch model should be recommended as the most cost-effective option for the technical rooms?

AHPE Aruba Networking 6300M 24p HPE Smart Rate 1G/2.5G/5G/10G Class6 PoE and 2p 50G and 2p 25G
BHPE Aruba Networking 6300M 12p Class8 PoE and 36p Class6 PoE HPE Smart Rate 1G/2.5G/5G and 2p 50G and 2p 10G
CHPE Aruba Networking 6200M 36G 12SR5 Class6 PoE 4SFP+
DHPE Aruba Networking 6200M 24G Class4 PoE 4SFP+
Question #35Part 1Propose the solution

A global cruise-line company needs to modernize its existing fleet. It will refresh the ship’s “insides” to reduce costs and improve sustainability, replacing all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. The project starts with the smallest ship, which supports a maximum of 800 guests. Each ship has a LAN infrastructure with two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches reside in the ship’s MDF, while distribution switches reside in the IDFs. Each cabin and technical room receives one individual access switch. The ship’s cabling infrastructure will not be refreshed. Every IDF connects to the MDF using SMF, with two pairs available for the core-to-distribution interconnect. The SM fiber between the MDF and IDF is under 300 meters (980 ft) and is OS1. Each cabin connects to its IDF using one OM2 pair, at a maximum distance of 60 meters (200 ft). Each technical room connects to its IDF with one OM2 pair, at distances from 100 to 150 meters (320 to 500 ft). For every cabin/technical room, the customer wants to replace the current fanless 2530/2540 switches without altering requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. The WLAN uses 200/300 Series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements. The cruise-line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will offer 99.8% uptime, required to keep paid guest Wi-Fi continually operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed. Based on best practices and customer requirements, which switch series should be recommended for the core?

A8320 Series
B8360 Series
C8325 Series
D8400 Series
Question #36Part 1Propose the solution

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new six-story regional office building. The bottom two floors will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will offer public guest Wi-Fi. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants redundant RADIUS resources in each of its three geographical regions (AMER, EMEA, and APAC). A large office location in each region has sufficient VMware resources available. Each region has 5,000 clients, all of whom must perform either 802.1x wired or wireless authentication, as well as 802.1x authentication for one personal Wi-Fi device. All non-personal devices must also validate health with a local agent. An average of 500 guests are expected to be connected, with a maximum of 700 simultaneous connections using Guest Portal for Internet access. TACACS authentication will also be configured for a total of 1,200 evenly distributed NADs. To support virtual IPs and server redundancy in every region, how many Virtual Policy Manager Licenses are required?

Asix licenses, C3000V
Bsix licenses, C2000V
Cthree licenses, C3000V
Dthree licenses, C2000V
Question #37Part 1Analyze requirements

You are responding to a customer’s Request for Proposal (RFP) for a new network-infrastructure solution. The RFP describes the customer’s desired features and technical outcomes but does not specify several important design details. At this point in the proposal process, you must document the assumptions made to complete the design and address gaps in the RFP. These assumptions should represent reasonable expectations that guide the customer’s understanding of the solution and highlight areas that may require further clarification. What is a valid example of an assumption that should be presented to the customer in your RFP response?

AThe customer's budget has already been approved to fully fund the proposed solution.
BThe customer's technical staff is fully capable of providing ongoing support for the proposed solution.
CAll required vendor equipment will be available in time to meet the customer’s requested project schedule.
DAdequate space and power are available to rack and commission the proposed equipment.
Question #38Part 1Analyze requirementsSelect 2

You meet with a customer to update the network after the prior network manager has left the company for another role. Which methods can validate the current network state when the available network documentation is invalid? (Choose two.)

ABegin searching through file shares for old documentation and compare the files and drawings to each other.
BUse neighbor discovery protocols to learn neighbor relationships, document the connections, and build a topology from the learned information.
CPhysically examine the network devices to hand-over-hand validate the connections from device-to-device documenting the connections and cabling type if possible.
DInterview random company staff to gather the 'tribal knowledge' of how the network functions during normal operations and during degraded states.
EDocumenting existing network configuration and topology is not required because previous iterations of network designs are considered obsolete.

📢 Unlock Full Access to Success!

"The content displayed here is a promotional preview and contains only 50% of the actual exam database. To access the complete set of updated questions, please upgrade to the Full Version."

👉 Click the button and follow the instructions to secure your full access immediately!