HPE7-A03: Aruba Certified Campus Access Architect (HPE7-A03)

Master the HP / HPE Aruba Certified Campus Access Architect (HPE7-A03) (HPE7-A03) certification exam with 43 realistic practice questions covering WLAN, Troubleshooting, Performance Optimization, Switching.

4.8★★★★★(257 ratings)
20,833 studentsIntermediate
Prepare for the HP / HPE Aruba Certified Campus Access Architect (HPE7-A03) (HPE7-A03) certification with scenario-based practice questions modeled on real exam objectives. You will build practical confidence across key domains including WLAN, Troubleshooting, Performance Optimization, Switching. Each question includes structured answer options and hint answers to help you identify knowledge gaps quickly, reinforce core HP / HPE concepts, and pass the HPE7-A03 exam on your first attempt.

What you'll learn

  • WLAN
  • Troubleshooting
  • Performance Optimization
  • Switching
  • Network Resiliency and virtualization
  • Security

HPE7-A03

Lectures1
Questions41
Duration30 week
Students20,833

$20.00

Full Free Question Bank (41 Questions)

HPE7-A03: Aruba Certified Campus Access Architect (HPE7-A03) (HPE7-A03) Practice Questions & Verified Answers

Click any option to test your knowledge, or reveal the verified answer and detailed explanation below each question.

Question #1Part 1WLAN

A global cruise line company must refresh its current fleet. It will refresh the ship’s ‘insides’ to be cost-effective and improve sustainability. It will replace all WLAN/LAN hardware on the ship. As part of this refresh, the company will not change its existing security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. The company will begin with the smallest ship, which accommodates a maximum of 800 guests. Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches reside in the ship’s MDF, and the distribution switches reside in the IDFs. Each cabin and technical room receives one individual access switch. The ship’s cabling structure will not be refreshed. Each IDF connects to the MDF through SMF, with two pairs available for the core-to-distribution interconnect. The SM fiber length between the MDF and IDF is under 300 meters (980 ft), and the fiber type is OS1. Each cabin connects to the IDF through one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to the IDF through one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft). For every cabin/technical room, the customer wants to replace its current fan-less 2530/2540 switches without altering requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. Its WLAN infrastructure uses 200/300 series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements. The cruise line company will replace its current Internet connection before the LAN/WLAN refresh. The new Internet connection will provide 99.8% uptime, needed to keep paid guest Wi-Fi operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed. Based on best practices and the customer requirements, what is the correct WLAN approach?

AInstant OS6 deployment
BOS10 AP only deployment
COS8 campus deployment
DOS10 AP and gateway deployment
Question #2Part 1Troubleshooting

Which platforms can be used to demonstrate your solution to a customer?

Ayour own lab
BInnovation Zone
CCX Switch Simulator
DSupport Portal
ESolution Exchange
Question #3Part 1WLAN

Which alternative source is most appropriate for site surveys or simulations when floor plans are not available?

Afire escape plan
Bblank sheet of paper
Csimple wall drawings
DGoogle Maps
Question #4Part 1Performance Optimization

A customer wants the ability to view network usage. Which product would provide this visibility?

AUXI
BHPE Aruba Networking ClearPass
CHPE Aruba Networking Central
DOS 8.X
Question #5Part 1Switching

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to use modem best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail area will offer public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, with a mix of wired and wireless devices throughout the retail floors. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has decided that the more critical switch stacks supporting Contact Center resources must support greater than 600W of CL4 PoE and redundant power supplies. These stacks will contain approximately six members. What is the most economical switch series choice that meets these requirements?

ACX 6400
BCX 6100
CCX 6300F
DCX 6200M
Question #6Part 1Network Resiliency and virtualization

What is the recommended practice for using VSX at the core in a three-tier design?

AYou should implement VSX at the core when the aggregation layer is layer 3 only with OSPF-routed traffic forwarding between the core and aggregation layers.
BYou should never implement VSX at the core of a 3-tier redundancy core.
CVSX-lags allow the collapsed core to connect directly to services such as gateways and services only so long as spanning tree is used to prevent loops.
DYou should implement VSX at the core when the aggregation layer operates at layer 2 only.
Question #7Part 1Switching

‘Don't Buy at Us’ is a US-based retail company expanding into Europe. Its EMEA expansion includes a regional headquarters, HQ2, in The Netherlands. Its US-based headquarters, HQ1, was refreshed last year using the HPE Aruba Networking ESP architecture. You created the HQ2 design using the same two-tier design as HQ1. The high-level design is shown below. ![Question Image](https://cdn.examcademy.com/images/questions/1784464810488-yx6wcest.png) Switch BOM for this project based on Two Tier: - Collapsed Core: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC) - Access Stack: 10 x Stack of 6200F 48G Class4 PoE 4SFP+ 740W (each stack has 4 members, VSF with 10GbE VSF links) (2 x 10GbE uplink per stack) During the presentation of your design to the CTO of ‘Don't Buy at Us’, you were informed of the changes they want incorporated into the updated design. 1. HQ2 will include the EMEA regional distribution center (EMEA-DISTR) next to HQ2. 2. Only two pairs of OS1 are available between HQ2 and EMEA-DISTR. 3. The uplinks from all access stacks must increase to 2 x 25GbE; the fiber in HQ2 and EMEA-DISTRI is certified for 25GbE. 4. EMEA-DISTR requires at least 7 x stack of Aruba 48 ports switches (each stack has 4 members). Which answer, based on best practice, presents the correct Switch BOM for the updated design?

Acore: 2 x 8360-12C in VSX (ISL 2x100GbE DAC)aggregation: 2 x Aggregation stacks, each consists of 2 Aruba 8360-16Y2C in VSX (ISL 2x100GbE DAC, 2 x 25GbE uplinks per stack) access stack: 17 x stack of Aruba 6300F 48-port 1GbE Class 4 PoE and 4-port SFP56 (each stack has 4 members, VSF with 50GbE VSF links, 2 x 25GbE uplinks per stack)
Bcore: 2 x 8360-12C in VSX (ISL 2x100GbE DAC)aggregation: 2 x aggregation stacks, each consists of 2 Aruba 8360-16Y2C in VSX (ISL 2x100GbE DAC, 2 x 100GbE uplinks per stack) access stack: 17 x stack of Aruba 6300F 48-port 1GbE Class 4 PoE and 4-port SFP56 (each stack has 4 members, VSF with 50GbE VSF links, 2 x 25GbE uplinks per stack)
Ccore: 2 x 8360-12C in VSX (ISL 2x100GbE DAC)aggregation: 2 x aggregation stacks, each consists of 2 Aruba 8360-32Y4C in VSX (ISL 2x100GbE DAC, 2 x 100GbE uplinks per stack) access stack: 17 x stack of Aruba 6300F 48-port 1GbE Class 4 PoE and 4-port SFP56 (each stack has 4 members, VSF with 50GbE VSF links, 2 x 25GbE uplinks per stack)
Dcollapsed core: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC)access switch: 17 x stack of Aruba 6200F 48G Class4 PoE 4SFP+ 740W (each stack has4 members, VSF with 10GbE VSF links, 2 x 10GbE uplinks per stack)
Question #8Part 1Switching

‘Don't Buy at Us’ is a US-based retail company expanding into Europe, including EMEA through a regional headquarters, HQ2, in The Netherlands. Its US headquarters, HQ1, was refreshed last year using the HPE Aruba Networking ESP architecture. You have designed HQ2 using the same two-tier design as HQ1. The high-level design is shown below. ![Question Image](https://cdn.examcademy.com/images/questions/1784464810652-7u3evv7j.png) Switch BOM for this two-tier project: - Collapsed Core: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC) - Access Stack: 10 x Stack of 6200F 48G Class4 PoE 4SFP+ 740W (each stack has 4 members, VSF with 10GbE VSF links) (2 x 10GbE uplink per stack) During the design presentation to the CTO of ‘Don't Buy at Us,’ you were informed of the updated fiber infrastructure installed in HQ2. ![Question Image](https://cdn.examcademy.com/images/questions/1784464816171-b2ncuzv5.png) The core stack is installed in the MDF, and one access stack is installed in each IDF. Based on best practice, what is the most cost-effective update to the switch BOM?

Acore: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC)access stack: 10 x stack of Aruba 6200F 48G Class4 PoE 4SFP+ 740W (each stack has 4 members, VSF with 10GbE VSF links) (2 x 10GbE uplink per stack) optics: 12 x 10Gbit-SR + 8 x 10Gbit-LR
Bcore: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC)access stack: 10 x stack of HPE Aruba Networking 6200M 48G Class4 PoE 4SFP+ (each stack has 4 members, VSF with 10GbE VSF links) (2 x 10GbE uplink per stack) optics: 12 x 10Gbit-SR + 8 x 10GbiLLR
Ccore: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC)access stack: 10 x stack of Aruba 6200F 48G Class4 PoE 4SFP+ 740W (each stack has 4 members, VSF with 10GbE VSF links) (2 x 10GbE uplink per stack) optics: 10 x 10Gbit-SR + 10 x 10Gbit-LR
Dcore: 2 x 8360-16Y2C in VSX (ISL 2x100GbE DAC)access stack: 10 x stack of HPE Aruba Networking 6200M 48G Class4 PoE 4SFP+ (each stack has 4 members, VSF with 10GbE VSF links) (2 x 10GbE uplink per stack) optics: 12 x 10Gbit-SR +8 x 10Gbit-LRM
Question #9Part 1WLANSelect 3

XYZ Regional Hospital is an integrated healthcare system comprising hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4 neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and must be replaced. XYZ Regional Hospital wants to future-proof and improve efficiency at all sites by improving wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability of every system. Locations: - XYZ Regional Hospital is in New York City. - Dila Health Center is in City

AAirWave
BAsset Tracking Subscription
CUser Experience Insight
DClient Insight
ETags Configuration App
Question #10Part 1WLANSelect 2

You are designing a solution using OS10-based access points and redundant gateways with these requirements: - Wi-Fi6E-based access points - Support for tunneled traffic - Application visibility - Rogue APs - Live upgrades - Air Slice - Cloud Guest Authentication - AI Insights Which licenses are required? (Choose two.)

AAP Foundation
BGateway Foundation
CAP Advanced
DWLAN Gateway
Question #11Part 1Troubleshooting

The current IT staff is accustomed to working with legacy OS-S (ProCurve) equipment. They are concerned that they may be unable to manage OS-CX switches because the command syntax differs. What are two ways to ease their transition?

ACLI Reference Guide for OS-CX, OS-Switch, Comware and Cisco IOS
BASP
CCLI Bank
Dcreate aliases
Question #12Part 1Troubleshooting

Which statement is accurate regarding device capabilities?

AYou should determine if devices support 2.4 GHz or 5 GHz. No consideration is yet required for 6 GHz as it has yet to be ratified.
BWi-Fi 6E supports 6 GHz for both indoor and outdoor deployments since it was ratified in April of 2020.
CHPE Aruba Networking's best practice is to use whatever the AP model supports as a maximum.
DHPE Aruba Networking recommends 40-50 devices per radio for a generic office deployment.
Question #13Part 1Security

The customer has recently learned that OS-CX switches support Application Recognition. Which requirements must be met to use it?

A6300F/M with CX Advanced License
B8360 with CX Advanced License
C6400 with CX Advanced License
D6200F/M with CX Advanced License
Question #14Part 1Security

A global cruise line company must refresh its current fleet. To control costs and improve sustainability, it will refresh the ship’s “insides,” including replacement of all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will always require a hardware refresh. The project begins with the smallest ship, accommodating a maximum of 800 guests. Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are installed in the ship’s MDF, and the distribution switches are installed in the IDFs. Every cabin and technical room receives one individual access switch. The ship’s cabling infrastructure will not be refreshed. Each IDF connects to the MDF using SMF, with two pairs available for the core-to-distribution interconnect. The MDF-to-IDF SMF run is under 300 meters (980 ft), and it uses OS1 fiber. Each cabin connects to the IDF with one OM2 pair, with a maximum distance of 60 meters (200 ft). Each technical room connects to the IDF with one OM2 pair, with distances from 100 to 150 meters (320 to 500 ft). For every cabin/technical room, the customer wants to replace its current fan-less 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. The WLAN uses 200/300 series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no WLAN requirement changes. The cruise line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will deliver 99.8% uptime, needed to keep paid guest Wi-Fi operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed. The week after presenting the design to the CIO of the cruise line company, the CIO calls to discuss increasing security for the wired network infrastructure. Because a competitor had one of its cruise ships cyber hacked, the CSO has mandated greater wired-network security. They have heard about dynamic segmentation and central and decentral overlay networks. What would you recommend as the most cost-efficient solution?

AStandardize on 6200 switches for the access layer, add a cluster of 9240 GWs, and implement central overlay networks on UBT basis.
BStandardize on 6300 switches for the access layer, add a cluster of 9240 GWs, and implement central overlay networks on UBT basis.
CStandardize on 6100 switches for the access layer, add a cluster of 9240 GWs, and implement central overlay networks on UBT basis.
DStandardize on 6000 switches for the access layer, add a cluster of 9240 GWs, and implement central overlay networks on UBT basis.
Question #15Part 1Security

A global cruise-line company must modernize its existing fleet. It will refresh the ship’s ‘insides’ to reduce cost and improve sustainability, including replacement of all WLAN/LAN hardware. This refresh will not change the company’s existing security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will require another hardware refresh. The company begins with its smallest ship, which accommodates a maximum of 800 guests. Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, while the distribution switches are in its IDFs. Every cabin and technical room receives one access switch. The ship’s cabling infrastructure will not be replaced. Each IDF connects to the MDF over SMF, with two pairs available for the core-to-distribution interconnect. The MDF-to-IDF SMF distance is under 300 meters (980 ft), and the fiber type is OS1. Each cabin connects to its IDF over one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to its IDF over one OM2 pair, at lengths from 100 to 150 meters (320 to 500 ft). For every cabin and technical room, the customer wants to replace the current fan-less 2530/2540 switches without altering the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to support increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. The WLAN uses 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no WLAN-requirement changes. The cruise-line company will replace its existing internet connection before the LAN/WLAN refresh. The new internet connection will provide 99.8% uptime, which is necessary to keep the paid quest Wi-Fi operational. Because this internet connection is guaranteed, the CIO wants the design based on Aruba ESP architecture. One week after you present the design to the CIO, the CIO calls to discuss increasing security for the wired network infrastructure. After a competitor’s cruise ship was cyber hacked, the CSO has mandated stronger wired-network security. They have heard about dynamic segmentation and centralized and decentralized overlay networks. The POS systems require a low-latency network connection between each POS system and the POS server in the ship’s data center. The CSO also wants to strengthen WLAN security by tunneling all user traffic. What solution meets the customer’s requirements?

AStandardize on 6200 switches for the edge, 8325 for the RR, 8360 for the stub/border, and utilize HPE Aruba Networking Central NetConductor.
BStandardize on 6300 switches for the edge, 8320 for the RR, 8360 for the stub/border, 9240 for the WLAN Gateway, and utilize HPE Aruba Networking Central NetConductor.
CStandardize on 6300 switches for the edge, 8320 for the RR, 8320 for the stub/border, 9240 for the WLAN Gateway, and utilize HPE Aruba Networking Central NetConductor.
DStandardize on 6300 switches for the edge, 8325 for the RR, 8360 for the stub/border, 9240 for the WLAN Gateway, and utilize HPE Aruba Networking Central NetConductor.
EStandardize on 6300 switches for the edge, 8320 for the RR, 8360 for the stub/border, and utilize HPE Aruba Networking Central NetConductor.
Question #16Part 1Switching

A global cruise-line company must modernize its existing fleet. To control costs and improve sustainability, it will refresh the ship’s internal systems and replace all WLAN/LAN hardware. This refresh will not change the current security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will always involve a hardware refresh. The project begins with the smallest ship, supporting a maximum of 800 guests. Each ship’s LAN consists of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, while the distribution switches are in the IDFs. Every cabin and technical room receives one access switch. The ship’s cabling will not be replaced. Each IDF connects to the MDF using SMF, with two pairs available for the core-to-distribution interconnect. The MDF-to-IDF SM fiber is OS1 and is less than 300 meters (980 ft). Each cabin connects to the IDF through a single OM2 pair, at a maximum distance of 60 meters (200 ft). Each technical room connects to the IDF through a single OM2 pair, with distances from 100 to 150 meters (320 to 500 ft). For every cabin and technical room, the customer wants to replace its current fanless 2530/2540 switches without changing requirements, except that the distribution-switch uplink must be upgraded to 10GbE for increased network traffic, and technical rooms require redundant power. The WLAN will be refreshed 1:1, with no new cabling or AP locations. It uses 200/300 Series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no WLAN requirement changes. The cruise-line company will replace its current Internet connection before the LAN/WLAN refresh. The new connection will offer 99.8% uptime, needed to keep paid guest Wi-Fi operational. Because this Internet connection is guaranteed, the CIO wants the design based on Aruba ESP architecture. Based on best practices, which switch model is the most cost-effective recommendation for the cabins?

AHPE Aruba Networking 6100 24G Class4 PoE 4SFP+
BHPE Aruba Networking 6100 12G Class4 PoE 2G/2SFP+
CHPE Aruba Networking 6000 12G Class4 PoE 2G/2SFP
DHPE Aruba Networking 6200F 12G Class4 PoE 2G/2SFP+
Question #17Part 1Switching

A German cruise-line company needs to modernize its existing fleet. To keep costs down and improve sustainability, it will refresh the ship’s internal systems, including all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize unused switch ports; any future expansion will require a hardware refresh. The work begins with the smallest ship, Ship One, which accommodates a maximum of 350 guests. Ship One’s LAN infrastructure consists of two core switches, eight redundant distribution switches, and 200 access switches (175 cabins and 25 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the ship’s eight IDFs. Each cabin and each technical room has a single access switch. The ship’s structured cabling will not be replaced. Each IDF connects to the MDF through SMF pairs. Each cabin connects to its IDF through a single MMF pair. Each technical room connects to its IDF through a single MMF pair. For every cabin and technical room, the customer wants to replace its current fanless 2530/2540 switch without changing requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to support increased network traffic. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. Its WLAN infrastructure uses 200-series indoor and outdoor APs running InstantOS (195 APs total), and the customer has no changes to WLAN requirements. A team member currently on parental leave started the proposed solution below. Core switch: one VSX stack of two 8325-48Y8C switches Distribution switch: one VSF stack of two 6300F 24-port SFP+ and 4-port SFP56 switches per IDF Cabin switch: one 6200F 12G Class4 PoE 2G/2SFP+ per cabin Technical room switch: one 6200F 12G Class4 PoE 2G/2SFP+ per technical room Indoor Cabin APs: AP-505H (88 total) Indoor standard APs: AP-535 (82 total) Outdoor APs: AP-565 (25 total) What potential issue do you identify with the core-switch selection relative to the customer’s requirements?

AThe core switch will not have enough ports for VSX links.
BThe core switch will have a lot of unused ports.
CThe core switch will not support the 10GbE downlinks to the cabins and technical rooms.
DThe core switch will not support the 25GbE downlinks to the distribution switches.
Question #18Part 1WLAN

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are outside this project’s scope. The customer is underserved by its current L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail area will offer public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mixture of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These upgrades will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants full wireless coverage in its 40 m x 40 m (130 ft x 130 ft) auditorium during company functions while using the fewest APs for aesthetic reasons. Wi-Fi6 APs are a minimum requirement. Which AP series would you use in the auditorium’s 1,000 seats with a maximum take rate of 80%?

AAP555
BAP577
CAP515
DAP635
Question #19Part 1WLANSelect 2

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new six-story regional office building. The bottom two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are out of scope for this project. The customer is underserved by its existing L2-based network infrastructure and wants to use modem best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and a mix of wired and wireless devices will be deployed throughout the retail floors. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has decided to market additional tools to its retail customers. It wants to make a Blue Dot wayfinding app available to any customer so they can locate stores and services within the retail space. It also wants directed pop-ups to appear within the app when a customer comes within close proximity of any of the 10 “Promotional Kiosks”. What licensing is required to make this retail solution a reality? (Choose two.)

Aqty 1 Meridian Map subscription
Bqty 10 HPE Aruba beacons
Cqty 2 Meridian Map subscriptions
Dqty 2 Meridian Blue Dot subscriptions
Question #20Part 1Authentication/Authorization

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new 6-story regional office building. The facility’s bottom two floors will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to adopt modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These improvements will support blue-dot wayfinding, presence analytics, and other location-based services. The client wants redundant RADIUS resources in each of its three geographical regions (AMER, EMEA, and APAC). A large office location is available in every region with sufficient VMware resources. - Each region has between 4,448 and 5,061 clients, all of which must perform either 802.1X wired or wireless authentications, as well as 802.1X authentication for a single personal device on Wi-Fi. - All non-personal devices must also validate health with a local agent. - A total of 500 guests are expected to be connected on average, with a maximum of 700 simultaneous connections using Guest Portal for Internet access. - TACACS authentication will also be configured for a total of 1200 evenly dispersed NADs. How many OnGuard Licenses are required in this scenario?

A30,000
B15,000
C20,000
D10,000
Question #21Part 1SwitchingSelect 2

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new six-story regional office building. The facility’s bottom two floors will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to adopt modern best practices in the new design. The network must be fully resilient and fault tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These upgrades will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has decided to manage two wiring closets as a single stack totaling 10 switches, with a minimum transport speed of 25Gbps over OM4 MM fiber. They also want to minimize stacking-cabling costs. Which stacking components are required to meet the customer’s requirements most cost-effectively when the closets are 190 m (620 ft) apart? (Choose two.)

A25G DAC cables
BSFP56 transceivers
CSFP28 transceivers:
D50G DAC cables
Question #22Part 1Switching

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new six-story regional-office building. The bottom two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate-office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its current L2-based network infrastructure and wants to take advantage of modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mixture of wired and wireless devices. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate-office space to take advantage of ‘smart office’ technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client has decided to manage two wiring closets as a single stack of 10 switches, with a minimum transport speed of 25Gbps over OM4 MM fiber. They also want to minimize the cost of stacking cabling. Which switch series would most economically meet these requirements?

A6200F Switch Series
B6300F Switch Series
C6100 Switch Series
D6400 Switch Series
Question #23Part 1Switching

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new six-story regional office building. The bottom two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and are outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to take advantage of modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These enhancements will support blue-dot wayfinding, presence analytics, and other location-based services. The client wants to use lower-cost OS-CX switches in its wiring closets. It has calculated that each closet will require a stack of qty 6 PoE (AT) and qty 4 Gigabit Ethernet switches, stacked with low-cost DACs. Which switch series should you recommend?

ACX 6200M
BCX 6000
CCX 6300F
DCX 6100
Question #24Part 1Security

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors will provide retail space for a large banking branch. The upper floors will be carpeted corporate-office space, with each floor measuring approximately 100,000 sq ft (9,290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its current L2-based network infrastructure and wants to apply modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail area will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate-office space to support ‘smart office’ technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants to provide Blue Dot wayfinding for the carpeted office space. The retail floors are currently out of scope. What is needed to ensure the solution is properly licensed?

AQty 4 Meridian Map subscriptionsQty 4 Meridian Blue Dot subscriptions
BQty 4 Meridian Blue Dot subscriptions
CQty 1 Meridian Blue Dot subscription
DQty 1 Meridian Tracking subscriptionQty 1 Meridian Blue Dot subscription
Question #25Part 1WLANSelect 2

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of this facility will be retail space for a large banking branch. The upper floors will be carpeted office space for corporate users, with each floor approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and are out of scope for this project. The customer is underserved by its existing L2-based network infrastructure and wants to take advantage of modem best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These improvements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants to include Blue Dot location tracking in its four floors of corporate space. The APs are not ideally located to enable smooth map transitions. What could be added to provide better tracking? (Choose two.)

AUXI sensors
Bmore APs
Cbeacons
Dtags
Question #26Part 1WLAN

ACME Retail operates 38 locations across five U.S. states and two Canadian provinces. It plans to grow by 20% during the next two years. Its HQ has 200 employees. The organization has eight Regional Managers and two VPs who work from home and while traveling. Stores typically average 17 employees per location. The two warehouses use a remote loading system and each has 20 employees who load trucks and fulfill online orders. Each warehouse has 40-foot ceilings and large metal inventory-storage racks. The main warehouse is 240K sq ft (22300 sq m), and the Canadian warehouse is 130K sq ft (12100 sq m). Forklifts on the loading docks have onboard wireless tablets. A typical store is reportedly about 60,000 sq ft (5575 sq m), and smaller 25,000 sq ft (2320 sq m) stores are planned. The locations need to extend capabilities to vendors who must add display setups or interactive kiosks in stores. The current infrastructure was installed in 2015 and uses wireless N technology in a coverage-based model. Cabling is Cat5, and the fiber connections are uncertain. Inventory is placed on the floor when delivered to local stores. Inventory control uses Zebra barcode scanners, and unreliable signals throughout stores make monthly inventory difficult. A small help desk troubleshoots retail-location issues and provides PC support for the office. The company plans to replace its current PBX system later this year. To support growth and lower costs, it is interested in moving data to the cloud, but the online service requires almost real-time inventory control. The network was wired over the last ten years, but new systems are wireless. The organization has seen a need to provide wireless access to vendors, employees, guests, and contractors. A new IT director starts next week, and the CTO has established the project. Marketing wants to interact with customers and obtain more information, while the IT support desk must reduce its staff by half. The office has an MDF and two IDFs on floors one and two. The MDF is in the basement, and multiple WAN circuits provide HQ links. Each store has a local Ethernet handoff from the cable provider in the office at the center of the store, so wiring distance is not a concern. The customer has budget constraints but wants a solution that can last 7+ years. Based on best practices and the customer requirements, what is the appropriate WLAN approach?

AInstant OS8 deployment
BOS10 AP and gateway deployment
COS8 campus deployment
DOS10 AP only deployment
Question #27Part 1SecuritySelect 2

Which statements are true regarding HPE Aruba Networking Central licensing for gateways? *(Choose two.)*

ASD-WAN Gateway functionality requires security licensing.
BGateway normal licensing is subdivided into three categories: Foundation, Advanced, and Foundation Base.
CWLAN Gateway licenses allow normal SD-Branch features within a campus.
DSD-Branch Gateway licenses allow normal WLAN Gateway features within a campus.
Question #28Part 1Network Resiliency and virtualization

Under which condition is a Mode Conditioning Patch Cable required?

AA 10GBase-LR Transceiver is operated with 62.5/125 cables up to 500 m.
BA 10GBase-LX4 Transceiver is operated with 62.5/125 cables up to 2 km.
CA 1000Base-LX Transceiver is operated with 62.5/125 cables up to 500 m.
DA 1000Base-SX Transceiver is operated with 62.5/125 cables up to 500 m.
Question #29Part 1TroubleshootingSelect 3

You are responding to the customer's RFP and are documenting design decisions that were not specified in the RFP or its questions. Which are valid examples of assumptions that should be presented to the customer in the response? (Choose three.)

AThe customer has technical staff that is capable of implementing the proposed equipment.
BThe customer budget is sufficient to afford the proposed solution.
COptional monitoring systems (syslog, flow collectors) exist.
DSufficient space and power exist to rack and turn up the proposed equipment.
EVendor equipment availability will meet customer project timelines.
Question #30Part 1Security

A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor measuring approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and are out of scope for this project. The customer is underserved by its existing L2-based network infrastructure and wants to take advantage of modem best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and a mix of wired and wireless devices will be deployed throughout the retail floors. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These improvements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client decides that all exposed printer, conference-room, and VoIP phone connections should be controlled by a stateful firewall. What could be planned to ensure these ports meet the customer's requirements?

ATunneled Node
BMulti-Zone
CWeb Portal
DAirgroup
Question #31Part 1Authentication/Authorization

A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new 6-story regional office building. The bottom two floors of the facility will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and are out of scope for this project. The customer is underserved by its existing L2-based network infrastructure and wants to adopt modem best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge. The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, but several wired clients, printers, and hard VoIP phones will also be used. The customer also plans to renovate the corporate office space to take advantage of ‘smart office’ technology. These improvements will enable blue-dot wayfinding, presence analytics, and other location-based services. The client wants redundant RADIUS resources in each of its three geographical regions (AMER, EMEA, and APAC). A large office location is available in each region with sufficient VMware resources. - Each region has 5,000 clients, all of which must perform either 802.1x wired or wireless authentication, as well as 802.1x authentication for one personal Wi-Fi device. - All non-personal devices must also validate health with a local agent. - A total of 500 guests are expected to be connected on average, with a maximum of 700 simultaneous connections using Guest Portal for Internet access. - TACACS authentication will also be configured for a total of 1,200 evenly distributed NADs. To support virtual IPs and server redundancy in each region, how many Virtual Policy Manager Licenses are required?

Asix licenses, C3000V
Bsix licenses, C2000V
Cthree licenses, C3000V
Dthree licenses, C2000V
Question #32Part 1Security

A global cruise-line company needs to refresh its current fleet. It will refresh the ship’s “insides” to be cost-effective and improve sustainability. The company will replace all WLAN/LAN hardware on the ship. During this refresh, it will not change its current security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. The company begins with the smallest ship, which has a maximum of 800 guests. Each ship has a LAN infrastructure with two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Each cabin and technical room receives one individual access switch. The ship’s cabling structure will not be refreshed. Each IDF connects to the MDF by SMF, with two pairs available for the interconnect between core and distribution. The SM fiber length between the MDF and IDF is under 300 meters (980 ft), and the fiber type is OS1. Each cabin connects to the IDF through a single OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to the IDF by a single OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft). For every cabin/technical room, the customer wants to replace the existing fan-less 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. Its WLAN infrastructure uses 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements. The cruise-line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will offer 99.8% uptime, needed to keep paid guest Wi-Fi operating continuously. Because this Internet connection is guaranteed, the CIO wants the design based on Aruba’s ESP architecture. One week after presenting the design to the CIO, the CIO calls to discuss increasing security on the wired network infrastructure. Because a competitor had a cruise ship compromised by a cyberattack, the CSO has mandated stronger wired-network security. They have heard about dynamic segmentation and central and decentral overlay networks. For POS systems, they require a low-latency network connection between the POS system and the POS server in the onboard data center. What solution meets the customer’s requirements?

AStandardize on 6300 switches for the edge, 8325 for the RR, 8360 for the stub/border, 9240 for the WLAN Gateway, and utilize Aruba Central NetConductor.
BStandardize on 6300 switches for the edge, 8320 for the RR, 8360 for the stub/border, 9240 for the WLAN Gateway, and utilize Aruba Central NetConductor.
CStandardize on 6200 switches for the edge, 8325 for the RR, 8360 for the stub/border, and utilize Aruba Central NetConductor.
DStandardize on 6300 switches for the edge, 8320 for the RR, 8360 for the stub/border, and utilize Aruba Central NetConductor.
EStandardize on 6300 switches for the edge, 8325 for the RR, 8360 for the stub/border, and utilize Aruba Central NetConductor.
Question #33Part 1Switching

A global cruise-line company must modernize its current fleet. To be cost-effective and improve sustainability, it will refresh the ship’s internal infrastructure and replace all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize unused switch ports, and any future expansion will always involve a hardware refresh. The work starts with the smallest ship, which accommodates a maximum of 800 guests. Each ship has a LAN infrastructure with two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Every cabin and technical room receives one individual access switch. The ship’s cabling infrastructure will remain unchanged. Each IDF connects to the MDF using SMF, with two pairs available for the interconnect between core and distribution. The MDF-to-IDF SM fiber is under 300 meters (980 ft) and is OS1. Each cabin connects to its IDF through a single OM2 pair, with a maximum distance of 60 meters (200 ft). Each technical room connects to its IDF using a single OM2 pair, with distances from 100 to 150 meters (320 to 500 ft). For every cabin and technical room, the customer plans to replace the current fan-less 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to support increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. It uses 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no change in WLAN requirements. The cruise-line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will offer 99.8% uptime, needed to keep the paid quest Wi-Fi operational. With this new Internet connection, the CIO wants the design to use Aruba’s ESP architecture because the Internet connection is guaranteed. Based on best practices and the customer requirements, what is the correct LAN approach?

Amanagement and user VLANs in the underlay
Bmanagement VLAN in the overlay, user VLANs in the underlay
Cmanagement VLAN in the underlay, user VLANs in the overlay
Dmanagement and user VLANs in the overlay
Question #34Part 1WLAN

A global cruise-line company needs to refresh its existing fleet. They will refresh the ship’s ‘insides’ to be cost-effective and improve sustainability. They will replace the ship’s complete WLAN/LAN hardware. During this refresh, the company will not change its current security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. They begin with the smallest ship, supporting a maximum of 800 guests. Each ship has a LAN infrastructure consisting of two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are located in the ship’s MDF, and the distribution switches are located in the IDFs. Each cabin and technical room receives one individual access switch. The ship’s cabling structure will not be refreshed. Each IDF connects to the MDF using SMF, with two pairs available for the interconnect between core and distribution. The SM fiber length between MDF and IDF is under 300 meters (980 ft), and it is OS1. Each cabin connects to the IDF through one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to the IDF through one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft). For every cabin/technical room, the customer wants to replace its current fan-less 2530/2540 without changing requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power. The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. Their WLAN infrastructure uses 200/300 series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements. The cruise-line company will replace its current internet connection before the LAN/WLAN refresh. The new internet connection will provide 99.8% uptime, needed to ensure the paid guest Wi-Fi remains operational. With this new internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the internet connection is guaranteed. Based on best practices, what optic type should be recommended for the connection between the IDF and the cabins?

A10G SFP+ LC SR 300 m MMF Transceiver
B10G SFP+ LC LRM 220 m MMF Transceiver
C10G LC BiDi 40 km-D 1330/1270 XCVR
D10GBASE-T SFP+ RJ-45 30 m Cat6A Transceiver
Question #35Part 1Network Resiliency and virtualization

What are the benefits of using a VSX pair rather than two separate switches to connect servers, storage, firewalls, and other workloads?

AYou can save half the number of licenses needed for AFC.
BThe setup is much easier since both switches are sharing the same configuration.
CBoth members in a VSX-pair can be upgraded without any downtime for the workload.
DVMWare-Host can be connected with or without using LACP, regardless of their license.
Question #36Part 1Security

XYZ Regional Hospital is an integrated healthcare system consisting of hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4 neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and require replacement. XYZ Regional Hospital wants to future-proof and improve efficiency at every site by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability of all systems. Locations: - XYZ Regional Hospital is located in New York City. - Dila Health Center is located in City

A• 1x 3010 as a Publisher for the main DC• 1x 3010 as a Standby Publisher for the DR• 2x 3010 as Subscribers for the Main Hospital• 2x C2020 as Subscribers for the Dila Health Center• 2x C2020 as Subscribers for the Mount Health Center• 2x C2020 as Subscribers for the Rock Health Center• 25k + 10k Access licenses
B• 1x 3010 as a Publisher for the main DC• 1x C2020 as a Standby Publisher for the DR• 2x C2020 as Subscribers for the Main Hospital• 2x C1000 as Subscribers for the Dila Health Center• 2x C1000 as Subscribers for the Mount Health Center• 2x VMs as Subscribers for the Rock Health Center• 15k + 10k Access licenses
C• 1x 3010 as a Publisher for the main DC• 1x 3010 as a Standby Publisher for the DR• 2x 3010 as Subscribers for the Main Hospital• 2x C1000 as Subscribers for the Dila Health Center• 2x VMs as Subscribers for the Mount Health Center• 2x C2020 as Subscribers for the Rock Health Center• 15k + 10k Access licenses
D• 1x C3010 as a Publisher for the main DC• 1x C3010 as a Standby Publisher for the DR• 2x C3010 as Subscribers for the Main Hospital• 2x C1000 as Subscribers for the Dila Health Center• 2x VMs as Subscribers for the Mount Health Center• 2x VMs as Subscribers for the Rock Health Center• 35k Access licenses
Question #37Part 1Switching

What is the basic difference between a main distribution framework (MDF) closet and an intermediate distribution framework (IDF) closet?

AMDF is the point where traffic egresses the campus network, and IDFs distribute that connectivity throughout the building.
BMDF is a term used in Europe whereas the Americas refer to all network closets as IDFs in their documentation.
CMDFs only connect to other MDFs, and IDFs only connect to other IDFs.
DMDFs always have larger rooms than IDFs.
Question #38Part 1TroubleshootingSelect 3

Which documentation resources can be used to locate validated information on HPE Aruba Networking products that helps the architect build the solution design? (Choose three.)

Adata sheets
Bvalidated Solution Guide
Ccompetitive documentation
DGartner annual reports
Eproduct reviews (CNET, Network World)
Question #39Part 1Troubleshooting

You are presenting your network design solution to a customer. What is important to include in the presentation?

Atangible and intangible returns for the customer
Bprotocols that will be used to make your solution work
Cyour experience with this kind of project
Dyour rollback plan
Question #40Part 1ConnectivitySelect 2

What distinguishes OM4 cabling from OM5 cabling? (Choose two.)

AOM5 supports Multiplexing operating in the 850 to 950 nm range, while OM4 does not.
BOM4 supports distances up to 100 m, while OM5 supports distances up to 150 m using 100 Gbps transceivers.
COM5 is approved as Wide Band Multimode Fiber (WBMMF), while OM4 is not.
DOM5 supports speeds up to 100 Gbps, while OM4 does not.
Question #41Part 1Network Resiliency and virtualization

Which factors should be considered when using existing MMF and upgrading equipment capable of 10 GbE speeds?

Asingle fiber tube into cabinet
Bredundant fiber tube into cabinet
Ctype of MMF fiber
Dtype of fiber connector
Elength of MMF fiber