Welcome to awslagi.com – Sharing AWS, Google Cloud, Microsoft Azure IT Exams. It's free for all!

HQT-4160: Hitachi Vantara Qualified Professional - VSP 5000 Series Installation

Master the Hitachi Vantara Hitachi Vantara Qualified Professional - VSP 5000 Series Installation (HQT-4160) certification exam with 18 realistic practice questions covering System Pre-Installation and Installation, Maintenance and Incident-Resolution, System Architecture, System Configuration.

4.8★★★★★(297 ratings)
19,161 studentsAdvanced
Prepare for the Hitachi Vantara Hitachi Vantara Qualified Professional - VSP 5000 Series Installation (HQT-4160) certification with scenario-based practice questions modeled on real exam objectives. You will build practical confidence across key domains including System Pre-Installation and Installation, Maintenance and Incident-Resolution, System Architecture, System Configuration. Each question includes structured answer options and hint answers to help you identify knowledge gaps quickly, reinforce core Hitachi Vantara concepts, and pass the HQT-4160 exam on your first attempt.

What you'll learn

  • System Pre-Installation and Installation
  • Maintenance and Incident-Resolution
  • System Architecture
  • System Configuration
  • Management Software

HQT-4160

Lectures1
Questions18
Duration30 week
Students19,161

$20.00

Full Free Question Bank (18 Questions)

HQT-4160: Hitachi Vantara Qualified Professional - VSP 5000 Series Installation (HQT-4160) Practice Questions & Verified Answers

Click any option to test your knowledge, or reveal the verified answer and detailed explanation below each question.

Question #1Part 1System Pre-Installation and InstallationSelect 2

A customer needs to upgrade a VSP 5500 to a VSP 5600. Which two actions are necessary for this upgrade? (Choose two.)

AReplace all the controller boards.
BReplace the CPUs on all the controller boards.
CReplace all the Power Supplies with more powerful ones.
DReplace all the memory DIMMs.
Question #2Part 1Maintenance and Incident-Resolution

On a VSP 5100, a drive in a RAID5 Parity Group has failed and has been blocked by the microcode. As a result, which process is automatically started?

ADynamic Sparing
BCorrection Copy
CCopy Back
DSparing Copy
Question #3Part 1System Pre-Installation and Installation

A VSP 5500 system is installed with a pair of Controller Boxes (CBXs). How many LAN cables are required to connect the controllers to the switch/HUB on Hitachi Service and Network Box-0 (HSNBX-0)?

A2
B4
C6
D8
Question #4Part 1System Pre-Installation and Installation

You are installing a VSP 5100. Which two DKU types are supported at level 1 in the DKU boxes?

ASBX
BUBX
CFBX
DDBS2
Question #5Part 1System Architecture

Which three RAID Group configurations does a VSP 5000 system support?

ARAID1 (2D+2D)
BRAID5 (4D+1P)
CRAID5 (7D+1P)
DRAID6 (6D+2P)
ERAID6 (7D+2P)
Question #6Part 1System Pre-Installation and Installation

You are installing a VSP 5000 system. It is connected to the power distribution, and you now want to power it on. Which three steps should you perform as part of the Power On sequence?

ATurn on the main breakers at the PDUs.
BCheck that the Power LED on all the CBXs are on.
CPress the LAN Reset Button on CBX 0.
DTurn on the PS ON/PS OFF switch on the HSNPANEL0.
EPress the Power Button on each CBX.
Question #7Part 1Maintenance and Incident-Resolution

Which two part replacements in a VSP 5000 system require the controller to be blocked?

AHitachi Interconnect Edge (HIE)
BController PCB
CCache DIMM
DCache Flash Module (CFM)
Question #8Part 1Maintenance and Incident-Resolution

You must perform a microcode upgrade on a VSP 5500H and want to back up the configuration first. How do you complete this task?

AUse Copy Config Files under the Initial Setting menu of the SVP GUI.
BConnect a USB drive to the SVP and use Copy Config Files.
CUse Copy Config Files under the Maintenance Utility.
DConnect the maintenance laptop to the SVP port and use Copy Config Files.
Question #9Part 1System Configuration

How is the internal SVP IP address configured on a VSP 5000 system?

AUsing the "Set IP Address" on the SVP GUI.
BIt is generated by the SSVP.
CThe Hitachi Distribution Centers pre-configure the same IP address on all new machines.
DIt must be set up by the customer’s network administrator.
Question #10Part 1System Configuration

Which three statements correctly describe the cache configuration of VSP 5000 systems with two controller boxes (CBX)?

AAll the DIMMs must be of the same type.
BCMG0 or CMG1 can be used as default cache.
CCMG0 must be used as default and CMG1 is optional.
DThe cache only support 128 GB DIMMs.
EEach controller pair (CTL1-CTL1, CTL2-CTL2) must have the same cache capacity.
Question #11Part 1System Architecture

Which two components differ between the VSP 5500 and VSP 5600 systems?

AInterconnect Switch (ISW)
BController Board
CHitachi Interconnect Edge (HIE)
DDKC Power Supply (DKCPS)
Question #12Part 1System ConfigurationSelect 3

You need to create Parity Groups on a VSP 5100. Which three actions are required? (Choose three.)

AUse Storage Navigator to create the Parity Groups.
BUse the Maintenance Utility to add the drives that you want to allocate to these Parity Groups.
CUse the Maintenance Utility to choose the drive allocation method (Manual or Automatic).
DUse the Web Console to select the appropriate drive type.
EMount the drives in the appropriate slots of the Disk Unit (DKU).
Question #13Part 1System Architecture

How many Channel Boards (CHBs) can be installed in a VSP 5600 with two CBX units?

A8
B12
C16
D24
Question #14Part 1System Architecture

Which statement correctly describes the Interconnect Switches (ISWs) in VSP 5000 systems?

AISWs are switches that provide redundancy for data path and they are only used when the number of CBX pairs is higher than two.
BISWs are switches that route data between nodes using Hitachi Interconnect Edge and X-Path cables, and they are located on the Hitachi Service and Network Boxes (HSNBXs).
CISWs are switches that route data between nodes and they are located on each controller of the node.
DISWs are standalone, optional switches than can be used for both network and data path.
Question #15Part 1System Pre-Installation and Installation

A customer intends to upgrade a diskless VSP 5100 to a VSP 5500. Which three component types are added during the upgrade?

AControllers (CTLs)
BInterconnect Switches (ISWs)
CChannel Boards (CHBs)
DHitachi Interconnect Edges (HIEs)
EHitachi Service and Network Box (HSNBX)
Question #16Part 1Maintenance and Incident-Resolution

You must upgrade the cache on a VSP 5500 while it remains online. How can you complete this task?

AUse the Maintenance Utility to block the controllers one at the time, and add the extra cache to the blocked controller.
BUse the Web Console to block the controllers one at the time, and add the extra cache to the blocked controller.
CUse Storage Navigator to put the CHB Adapters offline one controller at a time, and add the extra cache to the inactive controller.
DUse the VSP GUI and click on Change Configuration and follow the instructions on the screen to add the extra cache.
Question #17Part 1Maintenance and Incident-Resolution

Which two statements are accurate about the spare drive in a VSP 5000 system?

AOnly slot 11 and slot 23 of DBS2 can be used as spare.
BThe customer can decide which slot is to be used for the spare drive.
CIf one of the slot 11 of the SBX is used as spare, the 3 remaining slots 11 could only be used as spare.
DThe VSP 5000 system will allocate a spare slot automatically if "Spare slot allocation" is set to "Variable" at installation time.
Question #18Part 1Management Software

Which management tool is used to create a Parity Group on a VSP 5000 system?

AMaintenance Utility
BHitachi Command suite
CStorage Navigator 2
DWeb Console